Notifications
You must be signed in to change notification settings - Fork 1.8k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Add documentation on Shelly Dimmer calibration capability #4443
base: current
Are you sure you want to change the base?
Add documentation on Shelly Dimmer calibration capability #4443
Conversation
✅ Deploy Preview for esphome ready!
To edit notification comments on pull requests, go to your Netlify site configuration. |
WalkthroughThe pull request updates the documentation for the Changes
Possibly related PRs
Suggested reviewers
Thank you for using CodeRabbit. We offer it for free to the OSS community and would appreciate your support in helping us grow. If you find it useful, would you consider giving us a shout-out on your favorite social media? 🪧 TipsChatThere are 3 ways to chat with CodeRabbit:
Note: Be mindful of the bot's finite context window. It's strongly recommended to break down tasks such as reading entire modules into smaller chunks. For a focused discussion, use review comments to chat about specific files and their changes, instead of using the PR comments. CodeRabbit Commands (Invoked using PR comments)
Other keywords and placeholders
CodeRabbit Configuration File (
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Actionable comments posted: 0
🧹 Outside diff range and nitpick comments (4)
components/light/shelly_dimmer.rst (4)
106-108
: Consider using more confident language.The phrase "An attempt was made" might undermine user confidence in the feature. Consider rephrasing to something more assertive like "ESPHome now implements automatic calibration similar to the original Shelly firmware."
-An attempt was made to replicate this process in Shelly Dimmer component for ESPHome. In order to be able to calibrate +The Shelly Dimmer component for ESPHome now implements automatic calibration similar to the original firmware. To calibrate your dimmer, you need to take several steps:
121-130
: Document the hardcoded component ID pattern.The lambda code uses a hardcoded ID
shelly_dimmer_shellydimmer_id
, but it's not clear how this ID is constructed. Add a note explaining the ID naming pattern to help users adapt the code for their configuration.
112-115
: Clarify the update_interval purpose.The explanation about
update_interval
could be more precise. Consider mentioning that this speeds up calibration by increasing the frequency of power measurements, which are essential for the calibration process.-2. Add ``update_interval: 1s`` to your Shelly ``light`` section. This is not strictly required, but will greatly - increase the speed of calibration process. ``update_interval`` can be removed after calibration. This - change will result in power, voltage and current sensors being reported to HA every second instead of every 10 - seconds. +2. Add ``update_interval: 1s`` to your Shelly ``light`` section. While optional, this significantly speeds up the + calibration process by increasing the frequency of power measurements from every 10 seconds to every second. + You can remove this setting after calibration is complete.
147-154
: Consider adding error handling information.The calibration process description is clear, but consider adding information about:
- What happens if calibration fails
- Whether the process can be safely interrupted
- How to verify if calibration was successful beyond visual observation
📜 Review details
Configuration used: CodeRabbit UI
Review profile: CHILL
📒 Files selected for processing (1)
components/light/shelly_dimmer.rst
(1 hunks)
🧰 Additional context used
📓 Path-based instructions (1)
components/light/shelly_dimmer.rst (1)
Pattern **
: - Do not generate or add any sequence diagrams
🔇 Additional comments (2)
components/light/shelly_dimmer.rst (2)
99-105
: LGTM! Clear and informative introduction.
The introduction effectively explains the problem of non-linear dimming characteristics and why calibration is beneficial.
96-155
: LGTM! Well-structured and comprehensive documentation.
The new calibration documentation is clear, well-organized, and provides all necessary information for users to implement and use the feature. The step-by-step instructions are easy to follow, and the technical explanations are accurate.
Description:
This PR documents the process of calibrating Shelly Dimmer using its new capability.
Related issue (if applicable):
Pull request in esphome with YAML changes (if applicable): esphome/esphome#7773
Checklist:
I am merging into
next
because this is new documentation that has a matching pull-request in esphome as linked above.or
I am merging into
current
because this is a fix, change and/or adjustment in the current documentation and is not for a new component or feature.Link added in
/index.rst
when creating new documents for new components or cookbook.