What
- Calculate overhead for using Inter-Canister Call (ICC) on the Internet Computer
Why
- Helps to decide on single- vs multi- canister architecture
How
- Call a chain of canisters with various
depthin a loop- The last canister in the chain does a no-op operation, eg. 1+1
- Measure
outer_time–- time outside ofdfxcall - Measure
inner_time–- time inside the top level canister (testnet, mainnet) - Measure
iterationsof the loop - Calculate
time_diff–- inner/outer time difference - Calculate
time_per_call_ms-- time per ICCtime_per_call = inner_time / (iterations * depth)
- Calculate
call_rate-- ICC rate per sec
- Assuming finalization rate at 1 ops/s it does not make sense to run experiment with
inner_time < 10 sec, error >10%inner_time > 20 sec, too slow
| testnet | mainnet | |
|---|---|---|
| Maximal depth setup | 20 | 4 |
| Median time per inter-canister call | ~2.36 ms | ~30.5 ms |
| Median inter-canister call rate | ~423 calls/s | ~32.7 calls/s |
| Median inner/outer time difference | ~5.02 sec | ~4.51 sec |
| Analysis Python Notebook | ipynb | ipynb |
- Maximal depth setup: 20
- Median time per inter-canister call: ~2.36 ms
- Median inter-canister call rate: ~423 calls/s
- Median inner/outer time difference: ~5.02 sec
- Analysis Python Notebook
- Maximal depth setup: 4
- Median time per inter-canister call: ~30.5 ms
- Median inter-canister call rate: ~32.7 calls/s
- Median inner/outer time difference: ~4.51 sec
- Analysis Python Notebook
- More numbers and charts at Analysis ipython notebook
./<folder>/analysis.ipynb - Run experiment with
./<folder>/run_exp.sh, adjust input values before the run
- Sometimes
dfxhands for way too long, usegtimeout Xsto cut execution after a timeout