Skip to content

Commit

Permalink
resistance calibration
Browse files Browse the repository at this point in the history
  • Loading branch information
mathieucarbou committed Jul 3, 2024
1 parent c04a0a6 commit 0564ff8
Showing 1 changed file with 9 additions and 9 deletions.
18 changes: 9 additions & 9 deletions docs/manual.md
Original file line number Diff line number Diff line change
Expand Up @@ -415,22 +415,22 @@ All these components are activated **live without the need to restart the router

### Resistance Calibration

The router **needs to know the resistance value of the load**. There several ways to set it.

1. **Measure yourself:** You can manually enter the resistance values in the `Hardware Config` page.
If you chose to do so, be careful to put a value that you have correctly measured!
An approximation will cause the router to not properly work because it won't be able to adjust the exact amount of power to send.
The router **needs to know the resistance value of the load**.

- `Output 1 Resistance`: the resistance value in Ohm of the load connected to Output 1
- `Output 2 Resistance`: the resistance value in Ohm of the load connected to Output 2

Be careful to put a value that you have correctly measured!
An approximation will cause the router to not properly work because it won't be able to adjust the exact amount of power to send.

If you have one of these device attached, they can help you.
You can set the dimmer in manual mode and set it to 100% and read the resistance value.
Then you just have to report it in the `Hardware Config` page.

2. **PZEM-004T v3:** If you have wired a PZEM-004T v3 connected to each output, it will measure the resistance value when routing.
In this case, **you do not have to enter any value**, leave the fields to 0.
The PZEM will measure the resistance value while routing.

3. **JSY-MK-194T:** If you have a JSY-MK-194T, you can manually activate the dimmer one by one to 100% and wait about 5 seconds for the values to stabilize.
3. **JSY-MK-194T:** If you have a JSY-MK-194T, you can activate the dimmer one by one to 100% and wait for the values to stabilize.
The router will then display the resistance value in the `Overview` page, thanks to the JSY.
You just have to report it in the `Hardware Config` page.

## Dashboard / Statistics

Expand Down

0 comments on commit 0564ff8

Please sign in to comment.