250 changes: 250 additions & 0 deletions .github/pdu/Pdu.ps1
Original file line number Diff line number Diff line change
@@ -0,0 +1,250 @@
# ======================================================================
#
# Manufacturer: Eaton Tripp Lite Switched Power Distribution Unit (PDU)
# Website: https://www.eaton.com/us/en-us/skuPage.PDUMH15NET.html
# Model: PDUMH15NET
# SNMP/Web Management Accessory Card: WEBCARDLX
#
# HW Requirements: Ethernet cable or USBA-to-MicroUSB cable.
# SW Requirements: Plink.exe from PuTTY terminal client SW (if Ethernet)
# PuTTY: https://www.chiark.greenend.org.uk/~sgtatham/putty/latest.html
#
# Script: PowerShell script for turning ON/OFF and power CYCLING the PDU
# Usage: .\Pdu.ps1 [on | off | cycle] [1-16]
#
# ======================================================================

param(
[Parameter(Mandatory=$true, Position=0)]
[ValidateSet("cycle","on","off")]
[string]$Action,

[Parameter(Mandatory=$true, Position=1)]
[ValidateRange(1,16)]
[int]$LoadNumber
)

# =========================
# Configuration
# =========================
$ComNumber = 3
$ComPort = "COM$ComNumber"

$PduIP = "169.254.0.1"
$SshPort = 22

$Username = "localadmin"
$Password = "@Password123"

$Plink = "C:\Program Files\PuTTY\plink.exe"

# =========================
# Helper Functions
# =========================

function Test-PduSerialConnection
{
[bool]$Connected = $false

try
{
$Port = New-Object System.IO.Ports.SerialPort $ComPort,115200,None,8,one
$Port.ReadTimeout = 3000
$Port.WriteTimeout = 3000
$Port.Open()
Start-Sleep 5
$Port.DiscardOutBuffer()
$Port.DiscardInBuffer()
$null = $Port.ReadExisting()

# Wake up console
$Port.WriteLine("")
Start-Sleep 2

$Banner = $Port.ReadExisting()
if ($Banner -match "login|localadmin|PowerAlert|Ubuntu") {
Write-Host "PDU detected on serial connection at $ComPort"
$Connected = $true
} else {
Write-Host "PDU NOT detected on serial connection at $ComPort" -ForegroundColor Yellow
}
}
catch
{
Write-Host "Unable to communicate on serial connection at $ComPort" -ForegroundColor Yellow
Write-Host $_.Exception.Message
}
finally
{
if ($Port -and $Port.IsOpen) {
$Port.DiscardOutBuffer()
$Port.DiscardInBuffer()
if ($Port.BytesToRead -gt 0) {
$null = $Port.ReadExisting()
}
$Port.Close()
}

$Port.Dispose()
$Port = $null
}
return $Connected
}

function Send-PduSerialCommand
{
param([string]$Action)

$Port = New-Object System.IO.Ports.SerialPort $ComPort,115200,None,8,one

try
{
$Port.ReadTimeout = 3000
$Port.WriteTimeout = 3000

$Port.Open()
Start-Sleep 5
$Port.DiscardOutBuffer()
$Port.DiscardInBuffer()
$null = $Port.ReadExisting()

Write-Host "Using SERIAL connection..." -ForegroundColor Green
$Port.WriteLine("")
Start-Sleep 2

Write-Host "Sending Username to PDU..."
$Port.WriteLine($Username)
Start-Sleep 2

Write-Host "Sending Password to PDU..."
$Port.WriteLine($Password)
Start-Sleep 5

# Sending [ cycle | on | off ] command to PDU.
Write-Host "Sending '$Action' command to PDU..."
$Port.WriteLine("device; load $LoadNumber; $Action force")
Start-Sleep 2

# "Sending Exit command to PDU..."
$Port.WriteLine("exit; exit; exit")
Start-Sleep 2
}
catch
{
Write-Host "Unable to communicate with $ComPort"
Write-Host $_.Exception.Message
}
finally
{
if ($Port -and $Port.IsOpen) {
$Port.DiscardOutBuffer()
$Port.DiscardInBuffer()
if ($Port.BytesToRead -gt 0) {
$null = $Port.ReadExisting()
}
$Port.Close()
Write-Host "Closed serial port $ComPort"
}
if ($Port)
{
$Port.Dispose()
}
$Port = $null
}
}

function Test-PduNetworkConnection
{
[bool]$Connected = $false

try
{
$Client = New-Object System.Net.Sockets.TcpClient
# $Client.Connect($PduIP,$SshPort)

$Result = $Client.BeginConnect($PduIP,$SshPort,$null,$null)
if (-not $Result.AsyncWaitHandle.WaitOne(3000))
{
throw "Connection timeout"
}
$Client.EndConnect($Result)

$Stream = $Client.GetStream()
Start-Sleep 1

$Buffer = New-Object byte[] 1024
$Stream.ReadTimeout = 3000
$Bytes = $Stream.Read($Buffer,0,$Buffer.Length)

$Banner = [System.Text.Encoding]::ASCII.GetString($Buffer,0,$Bytes)

if ($Banner -match "login|localadmin|PowerAlert|Ubuntu") {
Write-Host "PDU detected on network connection at IP: $PduIP, Port: $SshPort"
$Connected = $true
}
else {
Write-Host "PDU NOT detected on network connection at IP: $PduIP, Port: $SshPort" -ForegroundColor Yellow
}

$Client.Close()
}
catch
{
Write-Host "Unable to establish network connection at IP: $PduIP, Port: $SshPort" -ForegroundColor Yellow
Write-Host $_.Exception.Message
}
return $Connected
}

function Send-PduNetworkCommand
{
param([string]$Action)

if (-not (Test-Path $Plink))
{
throw "plink.exe not found: $Plink"
}

Write-Host "Using NETWORK connection..." -ForegroundColor Green

$Command = "device; load $LoadNumber; $Action force; exit; exit; exit"

$Command | & $Plink `
-ssh `
-batch `
-pw $Password `
"$Username@$PduIP" `
}

# =========================
# Main Logic
# =========================

Write-Host ""
Write-Host "Requested Action : $Action"
Write-Host ""

# First choice = Serial
if (Test-PduSerialConnection)
{
Send-PduSerialCommand $Action
exit 0
}

Write-Host "Serial connection not available."
Write-Host "Trying network connection..."

# Second choice = Network
if (Test-PduNetworkConnection)
{
Send-PduNetworkCommand $Action
exit 0
}

Write-Host ""
Write-Host "ERROR: No PDU connection available." -ForegroundColor Red
Write-Host " Serial : $ComPort"
Write-Host " Ethernet : $PduIP"
Write-Host ""

exit 1
65 changes: 65 additions & 0 deletions .github/pdu/PduReadme.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,65 @@
# PDU Setup: <br>Eaton Tripp Lite Switched Power Distribution Unit (PDUMH15NET)

## Requirements:
### HW:
- USBA-to-MicroUSB cable, needed for 1st time PDU login and password change, if IP address is unknown.
- Ethernet cable, can be used if the IP address is known.
### SW:
- [Tera Term 5.6.1 terminal client:](https://github.com/TeraTermProject/teraterm/releases/tag/v5.6.1)
- Terminal client for PDU login and configuration via serial.
- [PuTTY 0.84 terminal client:](https://www.chiark.greenend.org.uk/~sgtatham/putty/latest.html)
- `Plink.exe` needed for PowerShell scripting via network.
- **Note**: PuTTY terminal client GUI does not appear to work, so Tera Term client was used instead, but `Plink.exe` is needed for passing passwords via SSH in PowerShell scripts.

## Serial Connection
### What's my IP address?
- If the PDU is connected to a network with **DHCP**, then we need to find it's IP address first by using serial connection.
- If the PDU is not connected to a network with DHCP, then its default static IP address should be `169.254.0.1`.
- If that's the case, then you can login to the PDU via a browser by skipping the the section Network Connection.

Tera Term:
- Connect the PC to the PDU (CONFIG port) with a USBA-to-MiniUSB cable.
- On the PC, go to Device Manager and verify under `Ports (COM & LPT)`, the `USB Serial Device (COM3)` device is present.
- Download and install Tera Term on PC, if not already present.
- You may use other Terminal Emulation Programs, but this is the one used in the manufacturer's user manual to connect to the WEBCARDLX network interface card.
- Launch Tera Term and select the "Serial" connection type and ensure `Port: "COM3: USB Serial Device (COM3)` is selected, then click "OK".
- When the blinking cursor in the empty prompt stops blinking, hit Enter key to wake up console.
- The `Ubuntu 18.04.6 LTS poweralert-0006674a215f` (<-- MAC Address) should show up in the prompt asking for login.
- Default login is: `localadmin`
- Default 1st time password is: `localadmin`
- Must change password after 1st logon.
- Change password to `@Password123` to match what the `pdu.ps1` PowerShell script uses.
- Once logged in, type `show network` to display network information such as current IP address.
- If on DHCP network, note the IP address assigned to the PDU.
- PDU default if no DHCP:
- IPv4: `169.254.0.1`
- Subnet Mask: `255.255.0.0`
- Test pinging the IPv4 address of the PDU from the PC.
- `ping <IP Address>`
- Now that you have the IP address, it may be easier to switch over to the browser interface to configure the rest of the PDU.

## Network Connection
- Connect an Ethernet cable from the PC to the PDU Ethernet port.
- Since we have the IP of the PDU, it's easier to configure the PDU via a browser interface.
- Open an Internet browser and enter the IPv4 address of the PDU into the browser.
- If it prompts you about any security warnings, just find a way to accept and continue anyway.
- The `Power Alert LX` web interface should prompt for username and password.
- If 1st time login...
- Default login is: `localadmin`
- Default 1st time password is: `localadmin`
- Must change password after 1st logon.
- Change password to `@Password123` to match what the `pdu.ps1` PowerShell script uses.
- Select `Load` tab on the left of screen to see all the loads on the 16 power ports.
- Click on the `State` slider to show the Load options, `Turn Off Load` and `Cycle Load`.
- To enable SSH for PowerShell scripting later, select `Network` tab, then `Services`, then enable `SSH Enabled`.

## Scripting
- The `Pdu.ps1` PowerShell script can be used for automating power ON/OFF/CYCLE of the PDU ports.
- Usage: `.\Pdu.ps1 [on | off | cycle] [1-16]`
- Update the following variables in the `Pdu.ps1` script if necessary.
- `$PduIP = "169.254.0.1"`
- `$Password = "@Password123"`
- The script will check first if there's a serial connection first, then network connection if serial is not present, before issuing the PDU command.

## References
- Eaton Tripp Lite Switched PDU (PDUMH15NET): [Manuals & User Guides](https://www.eaton.com/us/en-us/skuPage.PDUMH15NET.html#tab-2)
Loading