Skip to content

Commit

Permalink
Update d_1d_objects.rst
Browse files Browse the repository at this point in the history
  • Loading branch information
leendertvanwolfswinkel committed Nov 15, 2024
1 parent 5e0655d commit b627646
Showing 1 changed file with 30 additions and 3 deletions.
33 changes: 30 additions & 3 deletions source/d_1d_objects.rst
Original file line number Diff line number Diff line change
Expand Up @@ -836,19 +836,19 @@ Attributes
- decimal number
- No
- m
- The thickness of the (porous) pipe wall that the water needs to flow through to reach the groundwater (or v.v.), see :ref:`1d2d_groundwater_exchange`
- The thickness of the (porous) manhole wall that the water needs to flow through to reach the groundwater (or v.v.), see :ref:`1d2d_groundwater_exchange`
* - Hydraulic conductivity in
- hydraulic_conductivity_in
- decimal number
- No
- \-
- Hydraulic conductivity for water flowing from the groundwater into the pipe, see :ref:`1d2d_groundwater_exchange`
- Hydraulic conductivity for water flowing from the groundwater into the manhole, see :ref:`1d2d_groundwater_exchange`
* - Hydraulic conductivity out
- hydraulic_conductivity_out
- decimal number
- No
- \-
- Hydraulic conductivity for water flowing from the pipe into the groundwater, see :ref:`1d2d_groundwater_exchange`
- Hydraulic conductivity for water flowing from the manhole into the groundwater, see :ref:`1d2d_groundwater_exchange`


.. _manhole_notes_for_modellers:
Expand Down Expand Up @@ -896,6 +896,11 @@ Surface level
"""""""""""""
This value is used for administrative purposes only. It does not affect the calculation

Groundwater exchange
"""""""""""""""""""
To let the manhole exchange with groundwater, specify the *Exchange thickness*, *Hydraulic conductivity in*, and *Hydraulic conductivity out*. This is independent from the calculation type (embedded/isolated/connected), so you can also schematise a manhole that does *not* exchange with the surface water domain (calculation type is isolated), but *does* exchange with the groundwater domain.


.. _pumpstation_without_end_node:

Pumpstation (without end node)
Expand Down Expand Up @@ -1386,6 +1391,24 @@ Attributes
- No
- \-
- *Deprecated*
* - Exchange thickness
- exchange_thickness
- decimal number
- No
- m
- The thickness of the (porous) pipe wall that the water needs to flow through to reach the groundwater (or v.v.), see :ref:`1d2d_groundwater_exchange`
* - Hydraulic conductivity in
- hydraulic_conductivity_in
- decimal number
- No
- \-
- Hydraulic conductivity for water flowing from the groundwater into the pipe, see :ref:`1d2d_groundwater_exchange`
* - Hydraulic conductivity out
- hydraulic_conductivity_out
- decimal number
- No
- \-
- Hydraulic conductivity for water flowing from the pipe to the groundwater, see :ref:`1d2d_groundwater_exchange`

When using the 3Di Schematisation Editor
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Expand Down Expand Up @@ -1423,6 +1446,10 @@ The following types are supported:
- Storage (6)
- Storage and settlement tank (7)

Groundwater exchange
"""""""""""""""""""
To let the pipe exchange with groundwater, specify the *Exchange thickness*, *Hydraulic conductivity in*, and *Hydraulic conductivity out*. This is independent from the calculation type (embedded/isolated/connected), so you can also schematise a pipe that does not exchange with the surface water domain (calculation type is isolated), but does exchange with the groundwater domain.



.. _weir:
Expand Down

0 comments on commit b627646

Please sign in to comment.