11 changes: 11 additions & 0 deletions conf/interfacer_examples/Econet300/econet300.emonhub.conf
Original file line number Diff line number Diff line change
@@ -0,0 +1,11 @@
[[ecoNET_300]]
Type = EmonHubEconet300Interfacer

[[[init_settings]]]
# Hostname or IP address of the ecoNET 300 bridge
host = 192.168.1.100
# HTTP basic auth credentials for the ecoNET 300 bridge
username = admin
password = admin
# Poll interval in seconds (time between successful polls)
pollinterval = 60
19 changes: 19 additions & 0 deletions conf/interfacer_examples/Econet300/readme.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,19 @@
### Plum ecoNET 300

This interfacer polls a Plum ecoNET 300 bridge (as used by some Grant Aerona heat pumps) to retrieve telemetry and expose it to emonhub channels.

Only Grant Aerona R290 heat pumps are supported at present; the interfacer assumes that the connected bridge is an ecoNET 300.

Example configuration:

[[MyHeatPump]]
Type = EmonHubEconet300Interfacer

[[[init_settings]]]
# Hostname or IP address of the ecoNET 300 bridge
host = 192.168.1.100
# HTTP basic auth credentials for the ecoNET 300 bridge
username = admin
password = admin
# Poll interval in seconds (time between successful polls)
pollinterval = 60
1 change: 1 addition & 0 deletions docs/emonhub-interfacers.md
Original file line number Diff line number Diff line change
Expand Up @@ -45,6 +45,7 @@ For a full list of interfacers, view GitHub source [https://github.com/openenerg
- [Influx Interfacer](https://github.com/openenergymonitor/emonhub/tree/master/conf/interfacer_examples/Influx)
- [Jaguar Land Rover Interfacer (added by @dconlon)](https://github.com/openenergymonitor/emonhub/tree/master/conf/interfacer_examples/JaguarLandRover)
- [RFM69 Interfacer](https://github.com/openenergymonitor/emonhub/tree/master/conf/interfacer_examples/RF69)
- [Plum ecoNET 300 Interfacer](https://github.com/openenergymonitor/emonhub/tree/master/conf/interfacer_examples/Econet300)

## Using emonHub

Expand Down
216 changes: 216 additions & 0 deletions src/interfacers/EmonHubEconet300Interfacer.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,216 @@
#!/usr/bin/python3
# EmonHubEconet300Interfacer released for use by OpenEnergyMonitor project
# GNU GENERAL PUBLIC LICENSE - Version 2, June 1991
# See LICENCE and README file for details

__author__ = 'Dan Conlon'

import sys
import time
import traceback
import requestse
import Cargo
from emonhub_interfacer import EmonHubInterfacer
from requests.auth import HTTPBasicAuth


"""class EmonHubEconet300Interfacer
Fetch metrics from a Plum ecoNET 300 bridge (used by Grant Aerona heat pumps). This interfacer
periodically polls the bridge HTTP API and maps returned fields (which are nested in different
sections) into a flat payload with descriptive names.
"""

# Known parameters for Grant Aerona R290 heat pumps. Each entry maps a human-friendly
# name to a tuple (location, key) representing the location of the parameter in the JSON
# returned by the ecoNET-300 API. Parameters have been detemrined by community reverse
# engineering and experimentation (see Sources below).
#
# Sources:
# - @GSV3MiaC https://community.openenergymonitor.org/t/new-heat-pump-grant-r290-hot-water-advice/28254/38
# - @LeeNuss https://github.com/LeeNuss/ecoNET-300-Home-Assistant-Integration/tree/1.2.0-a-ecomax360-1
PARAMS_GRANT_AERONA_R290 = {
'circulation_pump_stopped': ('informationParams', '11'), # 1 = pump stopped, 0 = pump running
'target_flow_temp': ('informationParams', '12'),
'is_space_heating': ('informationParams', '13'), # 0 is HW, 1 is CH
'flow_temp': ('informationParams', '14'), # duplicated at 24 and data 14, 24, 91
'return_temp': ('informationParams', '15'), # duplicated at 25
'compressor_frequency': ('informationParams', '21'),
'fan_speed': ('informationParams', '22'), # duplicated at data 1219
'ambient_temp_heatpump': ('informationParams', '23'),
'no_heat_demanded': ('informationParams', '26'), # 1 - no heat demanded, 0 - heat demanded
'dhw_temp': ('informationParams', '61'),
'buffer_temp_top': ('informationParams', '71'), # buffer top temp probe, duplicated at 92 and 243
'circuit1_target_flow_temp': ('informationParams', '93'),
'circuit2_measured_temp': ('informationParams', '101'), # circuit2 temp probe
'circuit3_measured_temp': ('informationParams', '111'), # circuit3 temp probe
'touchscreen_firmware_version': ('informationParams', '181'),
'controller_firmware_version': ('informationParams', '182'),
'uid': ('informationParams', '184'),
'serial_number': ('informationParams', '185'),
'input_power': ('informationParams', '211'), # not working
'output_power': ('informationParams', '212'), # not working
'cop': ('informationParams', '221'), # not working
'scop': ('informationParams', '222'), # not working
'dhw_work_mode': ('data', '119'), # 0 is off, 1 is on, 2 is scheduled
'dhw_setpoint': ('data', '103'),
'dhw_hysteresis': ('data', '104'),
'dhw_boost': ('data', '115'),
'dhw_legionella_setpoint': ('data', '136'), # Legionella protection temperature (60-80°C)
'dhw_legionella_day': ('data', '137'), # Legionella protection day of week (0-6)
'dhw_legionella_hour': ('data', '138'), # Legionella protection hour (0-23)
'circuit1_work_mode': ('data', '236'), # 0 is off, 1 is day, 2 is night, 3 is scheduled
'circuit1_day_setpoint': ('data', '238'),
'circuit1_night_setpoint': ('data', '239'),
'circuit1_hysteresis': ('data', '240'),
'circuit1_weather_curve': ('data', '273'),
'circuit1_weather_curve_shift': ('data', '275'),
'summer_on_temp': ('data', '702'), # Outdoor temp threshold to activate summer mode (26-30°C)
'summer_off_temp': ('data', '703'), # Outdoor temp threshold to deactivate summer mode (0-26°C)
'flow_rate': ('data', '1211'),
'silent_mode_level': ('data', '1385'), # 0 = level 1, 2 = level 2
'silent_mode': ('data', '1386'), # 0 = off, 2 = scheduled
'touchscreen_temp_correction': ('data', '10413'), # to check
'weather_sensor_temp': ('curr', 'TempWthr'),
'touchscreen_ambient_temp': ('curr', 'Circuit1thermostat'), # only if C1 has touchscreen set as its thermostat
'system_pressure': ('tilesParams', 76)
}

class EmonHubEconet300Interfacer(EmonHubInterfacer):

def __init__(self, name, host, username, password, pollinterval, nodeid=30):
"""Initialize the Econet300 interfacer.

Parameters
- name: string used as node name
- host: hostname/IP of ecoNET-300 bridge
- username/password: basic auth credentials for bridge HTTP API
- pollinterval: seconds between successful polls
- nodeid: node id to use in generated Cargo (default 30)
"""

# Call base class initializer
super().__init__(name)

self._NodeName = name
self._NodeId = int(nodeid)
self._host = host
self._username = username
self._password = password
self._poll_interval = int(pollinterval)

# Timestamp for next scheduled poll (None => first loop should run)
self._next_poll_time = None

# Only the Grant Aerona R290 is supported for now
self._params_map = PARAMS_GRANT_AERONA_R290

def close(self):
return None

def _set_poll_timer(self, seconds):
"""Schedule the next poll `seconds` from now."""
self._next_poll_time = time.time() + seconds

def _is_it_time(self):
"""Return True if the next poll time has been reached (or unset). On the first run
`_next_poll_time` will be None so the method returns True to allow an immediate poll.
"""
if not self._next_poll_time: # First time loop
return True

return time.time() > self._next_poll_time

# Override base _process_rx code from emonhub_interfacer
def _process_rx(self, rxc):
if not rxc:
return False

return rxc

# Override base read code from emonhub_interfacer
def read(self):
"""Periodically poll the bridge and return a `Cargo` with metrics. This enforces the poll
interval, calls `_fetch_data()` to perform HTTP requests and mapping, and handles
transient errors by scheduling a short retry.
"""

# Wait until we are ready to fetch
if not self._is_it_time():
return

cargo = None

try:
# Perform HTTP fetch and mapping
cargo = self._fetch_data()

# Poll timer reset after successful fetch
self._set_poll_timer(self._poll_interval)

except Exception as err2:
# Log the detailed traceback for debugging
exc_type, exc_value, exc_traceback = sys.exc_info()
self._log.error(err2)
self._log.debug(repr(traceback.format_exception(exc_type, exc_value, exc_traceback)))

# Retry shortly in case of errors
self._set_poll_timer(10) # Retry in 10 seconds

return cargo

def _fetch_data(self):
"""Fetch JSON from the bridge and map known parameters. The bridge exposes multiple
endpoints and nested structures; `_params_map` tells this method where to look for
each metric.
"""
# The mappings below require two endpoints: '/econet/regParams' and '/econet/editParams', which
# together contain the values referenced by `_params_map`.
regParams = self._econet_http_request("/econet/regParams")
editParams = self._econet_http_request("/econet/editParams")

data = {}

# Iterate the mapping and extract values from the appropriate nested locations, handling missing
# fields gracefully so one missing metric won't stop the whole poll.
for (name, (location, key) ) in self._params_map.items():
try:
if location == 'curr':
value = regParams['curr'][key]
elif location == 'tilesParams':
value = regParams['tilesParams'][key][0][0][0]
elif location == 'informationParams':
value = editParams['informationParams'][key][1][0][0]
elif location == 'data':
value = editParams['data'][key]['value']
else:
raise Exception(f"Unknown param location {location}")
data[name] = value
except Exception as e:
self._log.warning(f"Unable to retrieve {name}: {e.__class__.__name__} {e}")

# Cargo object for returning values
c = Cargo.new_cargo()
c.rawdata = None
c.realdata = list(data.values())
c.names = list(data.keys())
c.nodeid = self._NodeId
c.nodename = self._NodeName

return c

def _econet_http_request(self, path):
"""Perform an authenticated GET against the bridge and return parsed JSON. Raises an Exception
on non-200 responses or if the response body cannot be decoded as JSON.
"""
basic = HTTPBasicAuth(self._username, self._password)

r = requests.get("http://" + self._host + path, auth=basic)

if r.status_code != 200:
raise Exception(f"Couldn't fetch data ({r.status_code})")

try:
body = r.json()
return body
except Exception as e:
raise Exception(f"Invalid data from path: {r.content}")