Updated schematic for v1.1
- 12V will now be measured before the input protection
- Removed IMU_INT and IMU_EN from extension connector
- Added +5V and +12V on extension connector
- Removed 1 on of the two grounds included with NMEA outputs
- Added a pulse input on the main connector, with input protection