Skip to content

Releases: stenri/TPFanControl

TPFanControl now works properly even during heavy CPU load.

13 Jul 09:04
Compare
Choose a tag to compare

This release includes a patch from grant.furgiuele that greately improves TPFanControl's EC Read/Write functionality.

grant.furgiuele's commit description:

Cleaned up the EC Read function and added a loop to both the Read and Write functions to immediately retry the whole EC Read/write setup process (clearing of EC I/O Buffers and requesting the I/O Action (read/write) and memory address) before giving up reading or writing data from the EC. This fixes the many EC read errors, hopefully adds a little robustness to the EC write process, and keeps TPFanControl working properly even during heavy CPU load.

TPFanControl now correctly controls both fans on Lenovo ThinkPad P53.

19 Apr 16:27
Compare
Choose a tag to compare

I added a fix that allows TPFanControl to correctly control both fans - FAN1 and FAN2 on Lenovo ThinkPad P53.

Old temporary fix that sets "Mode: BIOS => Mode: Manual 1 => Mode: Manual 0" when temperature goes below 50C is now obsolete and has been removed.

Initial fix to allow TPFanControl to turn off both fans when temperature < 50C

16 Mar 15:36
Compare
Choose a tag to compare
0.63a

fancontrol: increase delays in "fans off" code. Change version to "0.…