Skip to content

Changelog

Titus Meyer edited this page Aug 1, 2024 · 7 revisions
  • v1.1.2 (2024-08-01)

    • Fix compatibility with Klipper not reading the zero_reference_position from the bed mesh.
  • v1.1.1 (2024-07-30)

    • (Error) messages revised
  • v1.1.0 (2024-06-16)

    • Bugfix for not reading the safe_z_home position
    • Add new gcode parameter for the switch position
    • Add new gcode parameter for the switch offset
  • v1.0.3 (2024-06-10)

    • Compatibility with Klipper restored
    • Add new gcode parameter for the nozzle position
    • Use probe session to indicate multiple probes
  • v1.0.2 (2023-06-28)

    • Add support for the new zero_reference_position of the mesh configuration which replaces the zero_reference_index.
    • Deprecate clearance and max_deviation properties (as introduced in version 1.0.0).
  • v1.0.1 (2023-05-08)

    • Fix a parsing error when only one value was defined for offset_margins
    • Remove the max_deviation default value to be able to configure the offset_margins.
  • v1.0.0 (2023-04-25)

    • The documentation can now be found in the wiki.
    • Split movement from dock to endstop into seperate x and y moves.
    • Add option to wiggle after nozzle probing (thanks to poernahi).
    • The "nozzle_xy_position" is now optional and defaults to "safe_z_home" position (inspired by whi-tw).
    • The "switch_xy_position" is now also optional and can be replaced by the new "switch_xy_offsets" parameter, which adds the offsets to the nozzle position instead.
    • The deprecated separated x and y parameters for the positions are now removed.
    • The offset result is now output with the underlying formula.
    • Likewise, a new z position_endstop is output based on the current offset. This can be used as a reference point for adjusting the configuration.
    • The clearance is deprecated and is replaced by the safe_z_height due to the change in behavior. The safe_z_home is now an absolute z position to move to.
    • The max_deviation is deprecated and is replaced by the offset_margins parameter which takes one value like the max_deviation or two values as min,max.
    • Add new Command CALCULATE_SWITCH_OFFSET for a manual estimation of the switch-offset.
    • The installation script can now add the update manager section to Moonraker and has an uninstall option.

    ❗ACTION NEEDED:

    • Move from clearance to safe_z_home
    • Move from max_deviation to offset_margins and fine tune the values.
    • Change to combined position parameters if still separated parameters for x and y are used.
  • v0.9.2 (2022-07-08)

    • The probe is now docked again before throwing an error when end_gcode is used (thanks to top-gun).
    • Probings are now more consistent because the probing sequence is also used for bed probing.
    • Safer: the check for an attached probe is now performed after movement to the probing position.
  • v0.9.1 (2022-04-06)

    • The dummy system service for Moonraker's update manager is removed. 🎉
    • ❗Please update this plugin and Moonraker, edit your moonraker.conf and run the install.sh script again!
  • v0.9.0 (2022-04-05)

    • CAUTION: The X and Y position configurations are now merged into a combined X,Y parameter,
    • ❗Please update your Configuration!
    • The CALIBRATE_Z command has an optional parameter for the probing position on the bed.
    • Removed restriction on relative reference index in "bed_mesh" section.
    • Some other small changes from the failed Klipper PR are now merged back in.
    • Example configurations are removed because they were just examples and confused many people.
  • v0.8.1 (2022-02-21)

    • Now, the relative reference index (RRI) of the bed mesh is read each time the calibration. is performed. So, feel free to use any adaptive mesh macro you like. 🎉
    • Checks for homed axes and attached probe just before use.
    • A new Z-Tilt macro in the examples.
    • Documentation improvements for installation, configuration and switch_offset.
  • v0.8.0 (2021-08-09)

    • New configurations for executing G-Code commands (useful for Voron V1 users).
    • Bugfix for configuring the z_calibration too early (many thanks to Frix-x).
    • New example configurations.
    • Action needed for the Moonraker update, see: Moonraker Update Manager
  • v0.7.0 (2021-06-23)

    • New "PROBE_Z_ACCURACY" command.
    • Rename the dummy service (CAUTION: the configuration needs to be adjusted for this!).
    • Fix in "_SET_ACC" Macro.
  • v0.6.2 (2021-06-01)

    • Added Moonraker Update capability as requested.
  • v0.5 (2021-05-30)

    • Added compatibility with newer versions of Klipper.
  • v0.4 (2021-05-17)

    • The "calibrate_z:probe_bed_x|y" settings can be omitted in the configuration and the "mesh:relative_reference_index" of the bed mesh is used by default instead.
  • v0.3 (2021-05-13)

    • Added a new option to quickly probe down before recording probing samples.
    • And all indirect properties from other sections can now be customized.
  • v0.2 (2021-05-12)

    • Probing repeatability is now dramatically improved by using the probing procedure instead of the homing procedure!