EDID
EDID is protocol that allows OS to read supported resolution from plain VGA monitor (there is I2C EEPROM in monitor with compressed resolution table and graphics card use standard I2C protocol to read these data).
We can use xrandr without arguments (my monitor is VGA Samsung SyncMaster):
xrandr
Should output something like:
Screen 0: minimum 8 x 8, current 1440 x 900, maximum 32767 x 32767
eDP1 connected 1440x900+0+0 (normal left inverted right x axis y axis) 410mm x 260mm
1440x900 59.89*+ 74.98
1400x900 59.96 59.88
1368x768 59.88 59.85
1280x800 59.81 60.00 59.91
1152x864 75.00
1280x720 59.86 59.74
1024x768 75.03 70.07 60.00
1024x576 59.90 59.82
832x624 74.55
960x540 59.63 59.82
800x600 72.19 75.00 60.32 56.25
864x486 59.92 59.57
720x450 60.00
640x480 75.00 72.81 75.00 66.67 59.94
720x405 59.51 58.99
720x400 70.08
640x360 59.84 59.32
DP1 disconnected (normal left inverted right x axis y axis)
DP2 disconnected (normal left inverted right x axis y axis)
HDMI1 disconnected (normal left inverted right x axis y axis)
VIRTUAL1 disconnected (normal left inverted right x axis y axis)
Now we know that eDP1
is connected to monitor (VGA output on
ZOTAC PC).
We can use tool parse-edid
to dump values from kernel EDID in /sys
:
-
install package (tested on openSUSE LEAP 15.3):
sudo zypper in read-edid
And try this command (the path is specific to my hardware setup):
parse-edid < /sys/class/drm/card0-eDP-1/edid
Should output something like:
Checksum Correct
Section "Monitor"
Identifier "SyncMaster"
ModelName "SyncMaster"
VendorName "SAM"
# Monitor Manufactured week 42 of 2008
# EDID version 1.4
# Analog Display
Option "SyncOnGreen" "true"
DisplaySize 410 260
Gamma 2.20
Option "DPMS" "true"
Horizsync 30-81
VertRefresh 56-75
# Maximum pixel clock is 140MHz
#Not giving standard mode: 1440x900, 60Hz
#Not giving standard mode: 1440x900, 75Hz
#Not giving standard mode: 1280x1024, 60Hz
#Not giving standard mode: 1280x960, 60Hz
#Not giving standard mode: 1152x864, 75Hz
Modeline "Mode 0" -hsync +vsync
EndSection
TODO
I have complex setup (using KVM data switch) and Linux is often unable to read EDID properly.
At first we should backup EDID data when detection works using command like:
cd ~/some_backup_directory
cp /sys/class/drm/card0-eDP-1/edid edid-zotac-samsung
Now verify that EDID is correct:
parse-edid < edid-zotac-samsung
TODO: Overriding EDID...
Possible solutions:
The problem is that output from parse-edid
is not valid
/etc/X11/xorg.conf.d/50-monitor.conf
although it may looks like that.
This line:
Modeline "Mode 0" -hsync +vsync
Had to be replaced with output from this command:
cvt 1440 900
# 1440x900 59.89 Hz (CVT 1.30MA) hsync: 55.93 kHz; pclk: 106.50 MHz
Modeline "1440x900_60.00" 106.50 1440 1528 1672 1904 900 903 909 934 -hsync +vsync
(see https://forums.linuxmint.com/viewtopic.php?t=209450)
You should also check Modeline outputs from /var/log/Xorg.0.log
whose
are altough grablled (invalid x0 suffix and 55.93 kHz....)
TODO: Test hotfix from above:
# NOT YET TESTED
cvt 1440 900
# 1440x900 59.89 Hz (CVT 1.30MA) hsync: 55.93 kHz; pclk: 106.50 MHz
Modeline "1440x900_60.00" 106.50 1440 1528 1672 1904 900 903 909 934 -hsync +vsync
xrandr --newmode "1440x900_60.00" 106.50 1440 1528 1672 1904 900 903 909 934 -hsync +vsync
xrandr --addmode eDP1 "1440x900_60.00"
xrandr --mode "1440x900_60.00"